Thursday, November 21, 2024

VENTILATION OUTAGE - CLSL-A - NOVEMBER 25TH FROM 6:00AM TO 9:00AM

TO ALL IN CLSL-A:

F&S will be conducting a VENTILATION OUTAGE affecting the listed rooms in CLSL-A on Monday, November 25th from 6:00AM to 9:00AM. This outage is needed to perform some work on the S-1 fan controls. This outage will only affect the supply/makeup air to these rooms so there will possibly be warmer than usual space temperatures. The lack of supply air will also diminish the effectiveness of the fume hoods so it is best to avoid using them during the outage. If fume hoods do need to be used, please keep the lab doors open to allow makeup air from the hallways to help keep the fume hoods working properly. Further details about the outage are listed below:
 
Outage Request Number: 72783

Outage Time : 2024/11/25 06:00 until 2024/11/25 09:00

Outage Type : VENTILATION

Building : 0070 - CHEMICAL & LIFE SCIENCES LABORATORY

Building Sections affected : A101-A107, A201-A207, A301-A307, A401-A407, & A501-A507

Building Services affected : ventilation and cooling

Building Occupants Effect : Warmer troom temps and loss of supply/makeup air

Ventilation Fan No. : S-1

Ventilation Area. : A101-A107, A201-A207, A301-A307, A401-A407, & A501-A507

Comments : null

Work order # : 11059848 0070 CHEM LIFE, ROOM BB01. SERVICE REQUEST - SHOP 55 - NN518-U16061/30001 LUMP SUM OWNER'S COST SHOP 55: PLEASE ADDRESS OPEN AIR CABLING FROM RETIRED JOHNSON METASYS SYSTEM. THIS WORK IS IN SUPPORT OF U16061 EPC PROJECT 005 BASA2. REGULAR. SHOP 55. **

Reason : shut down fan for controls switchover

If you have any further questions or concerns, please do not hesitate to email the SCS Facilities and Safety team at scs-facilities@illinois.edu. This information will also be available for viewing on the SCS Building Outages/Important Notices blog: https://buildingoutages.scs.illinois.edu/

Shane Brownfield, CCHO

Safety and Inventory Coordinator– School of Chemical Sciences

16 Roger Adams Lab

217-300-6618

sbrownfi@illinois.edu

Wednesday, November 6, 2024

VACUUM OUTAGE - SOUTH RAL - NOVEMBER 7TH FROM 7:00AM TO 9:00AM

TO ALL IN SOUTH RAL:

F&S will be conducting a VACUUM OUTAGE affecting South RAL on Thursday, November 7th from 7:00AM to 9:00AM. This outage is needed to complete repairs on the building vacuum system. During the outage, labs in South RAL (rooms x33-x79) will be without house vacuum. Further details about the outage are listed below:

Outage Request Number: 72727

Outage Time : 2024/11/07 07:00 until 2024/11/07 09:00

Outage Type : VACUUM SYSTEM (OTHER)

Building : 0116 - ROGER ADAMS LABORATORY

Building Sections affected : South RAL only

Building Services affected : Building vacuum

Building Occupants Effect : No Vacuum in labs

If you have any further questions or concerns, please do not hesitate to email the SCS Facilities and Safety team at scs-facilities@illinois.edu. This information will also be available for viewing on the SCS Building Outages/Important Notices blog: https://buildingoutages.scs.illinois.edu/

Shane Brownfield, CCHO

Safety and Inventory Coordinator– School of Chemical Sciences

16 Roger Adams Lab

217-300-6618

sbrownfi@illinois.edu