Tuesday, January 31, 2023

LOW PRESSURE STEAM OUTAGE - NOYES LAB - FEBRUARY 1ST FROM 6:00AM TO 12:00PM

TO ALL IN NOYES LAB:

F&S is conducting a LOW PRESSURE STEAM OUTAGE affecting Noyes Lab on Wednesday, February 1st from 6:00AM to 12:00PM. This outage is need to make repairs on the steam line. During the outage, building occupants may notice cooler than usual temperatures. Further details about the outage are listed below:=

Approved Outage Details:

Outage Request Number: 70983

Outage Time : 2023/02/01 06:00 until 2023/02/01 12:00

Outage Type : LOW PRESSURE STEAM

Building : 0012 - NOYES LABORATORY OF CHEMISTRY

Building Sections affected : Entire bldg

Building Services affected : Perimeter Heat

Building Occupants Effect : Cooler temps

Comments : null

Reason : To make repairs to end of main on steam line

If you have any further questions or concerns, please do not hesitate to email the SCS Facilities and Safety team at scs-facilities@mx.uillinois.edu. This information will also be available for viewing on the SCS Building Outages/Important Notices blog: www.scsbuildingoutages.blogspot.com

 

Shane Brownfield, CCHO

Safety/Environmental Compliance Coordinator– School of Chemical Sciences

94 Roger Adams Lab

217-300-6618

sbrownfi@illinois.edu

Wednesday, January 18, 2023

VENTILATION OUTAGE - CLSL-A - JANUARY 19TH FROM 6:00AM TO 7:00AM

TO ALL IN CLSL-A:

F&S will be conducting a VENTILATION OUTAGE affecting CLSL-A on Thursday, January 19th from 6:00AM to 7:00AM. This outage is needed to reinstall panels around the HR coil. During this outage, there will be no exhaust present in the fume hoods so no research should be taking place in them. To prepare for the outage, please make sure that all chemicals and waste containers are sealed and that the fume hood sashes are fully closed. Further details about the outage are listed below:

Outage Request Number: 69950

Outage Time : 2023/01/19 06:00 until 2023/01/19 07:00

Outage Type : VENTILATION

Building : 0070 - CHEMICAL & LIFE SCIENCES LABORATORY

Building Sections affected : "A" Building Labs

Building Services affected : Lab exhaust

Building Occupants Effect : fume hoods out of service

Ventilation Fan No. : EF-1/2/3

Ventilation Area. : "A" Building Labs

Comments : null

If you have any further questions or concerns, please do not hesitate to email the SCS Facilities and Safety team at scs-facilities@mx.uillinois.edu. This information will also be available for viewing on the SCS Building Outages/Important Notices blog: www.scsbuildingoutages.blogspot.com

 

Shane Brownfield, CCHO

Safety/Environmental Compliance Coordinator– School of Chemical Sciences

94 Roger Adams Lab

217-300-6618